LFP Management System for Lithium Ion Battery
Click image to view full size image
Product: Views:474LFP Management System for Lithium Ion Battery 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2024-11-27 21:50
  Inquiry
Details

Seplos 48V 200A 13S 14S NCM 15S 16S LFP Management System BMS 2.0 For Lifepo4 Lithium ion Battery

 

Features

 

With Bluetooth modules,user can manage the battery on the phone conveniently;

and with heating modules,user can make sure there is heat enough to run the battery Systems when temperature below 0 C or even below -20℃

 

BMS Functions

 

Monitoring:

Voltage: total voltage,voltages of individual cells minimum and maximum cell voltage

Temperature: environment temperature,temperature of cells and BMS PCB

State of charge: indicate the charge level of the battery

Current: current in or out of the battery

CANBUS 24/48V 8S/16S 200A lithium iron phosphate battery smart monitoring management system 1

 

Communication:

CANBUS communication

Our BMS can support up to 16 units in parallel operation

RS485 communicationRS485 can be customize)

PS:When we want to view the battery pack parameters through the battery parameter monitoring software we need to use the Rj45 to USB Adapter to connect the battery pack to the computer We recommend that you purchase an Rj45 to USB Adapter from us.Adapters purchased from the market may not work properly due to the definition of the hardware

 

Protection:

Over voltage protection

Capacity protection

Pre-chargeing function

Current limiting

Under voltage protection

Charge, discharge and ambient temperature protection

Charge and discharge over current protection

Charge current limitation

Short circuit protection

Custom function

Heating function

External switch

RS485protocol

Equalizing function

Passive equalization

Communication methods

CANBUS communication method

 

Now our CANBUS communication board supports these brands of inverters and our BMS has built-in CANBUS protocol of matching inverter brand which can be automatically matched or manually switched

 

The default is the Pylontech CANBUS protocol

Good we

Growatt (The default is SPF(off-grid)protocol.If your inverter is SPH(on-grid),please contact the sales person)

Victron

LUXPOWER

Sofar

Deye

Sermatec

Renac

TBBPOWER

Solis

SMA

Foxess

IMEON

PS:If the inverter brand not in the listed please ask your inverter supplier for the protocol define.And sent it to us,we II help confirm that

 

RS485 communication method

Now our RS485 communication board supports these brands of inverters The BMS with RS485 communication has a built-in RS485 protocol please confirm with the salesman before buying what you need is that one RS485 protocol:

 

The default is the Pylontech RS485 protocol

Voitronic

Phocos

Growatt

PS:If the inverter brand not in the listed please ask your inverter supplier for the protocol define And sent it ti us we'll help confirm that

 

FAQ

 

Q: Can the 485 version and CAN version of the V14 BMS change the baud rate of the BMS by refreshing the program?

A: NO they are different version of the chip

Q: Is it an equalizing function,active or passive and what is the equalizing current

A: It's a passive equalizing function with 150mA current

Q: What is the connection mode of communication when BMS communicates with inverter or 485 communication and CAN communication

A: External communication means that BMS is connected to CANBUS interface when communicating with inverter (RS485 interface is used for communication with Voltonic inverter)

Q: The BMS cannot work and indicator does not light up

A: May be caused byD4diode damage

Q: Which BMS model suitable for ternary lithium battery?

A: The ternary lithium battery can support up to 14S version of the BMS. The firmware version of the ternary lithium battery BMS is different from the lithium iron phosphate BMS and cannot be used universally

Q: SMA and Victron inverter will report fault when BMS is fully charged

A: The fault can be solved by refreshing the firmware program(version 2.8).The V16 BMS does not have this fault

Q: Voltronic inverter and its licensed inverter only have 485 communication version of BMS or new version of BMS V16 version). How to use the inverter

A: The Voltonic inverter uses RS485 interface for communication. DIP dialing is different from other versions of BMS.Connect and dial 1on to the host 2on to the first slave,and 3on to the second slave. You can ask me to Send relevant documents

Q: How is BMS function of SOC calculating and cycle life counting work

A: First,modify the rated capacity of the battery then complete a full charge and discharge process the actual battery capacity will be learned.SOC is calculated by capacity accumulation and voltage calibration.
It has the function of calculating the number of charging and discharging cycles.When the cumulative discharge capacity of the battery pack reaches the set full capacity.At 20% (default), the number of cycles increases one the set value of battery cycle capacity parameter can be changed through the upper computer

Q: The issue of battery monitoring software cannot see the master when multiple BMS are in parallel.

A: hen multiple BMS are in parallel, the battery monitoring software cannot see the information of the master only see the information of the slave. If you want to see the information of the master you need to turn off the DIP of the master and connect it separately or use the LCD screen with Bluetooth function or use the onboard BMS with Bluetooth function

Q: Why not message display on LCD screen

A: 1.The function of LCD did not open
2.Poor contact of connecting or broken wire of LCD screen.
3.The new version BMS with Bluetooth,but install with an LCD screen without Bluetooth

Q: limited algorithm of charge current

A: Unbalanced in current distributed.
1.no charge current if any device is in charging warning of voltage temperature,and capacity or charging protection.
2.charge current values remain in 10.0A when no device in charging.
3.charge current is base the role if over current is greater than 20.0A then reduce 10.0A,otherwise remain in 10.0A when single device is charging
4.charge current is base the role of over current value multiply by device's quantity then divide by two if more than two device is charging
5.charge current will be cleared and set the chargeable value to OA when any single cell voltage more than +30mV compare to over voltage protection value with battery pack in parallel12

Q: what if customer want to purchase BMS but the inverter in use is not in compatible list

A: Customer need to provide the communication protocol of their inverter

Q: Battery monitoring software not working or load protocol failure

A: 1.Download new program.2.set the correct format languagel (as below)

Q: The functions of heating and heating pad choosing.

A: BMS with heating function need to customized because the heating pad size is not specific,customer need to purchased by themself and current can not over 4A

Q: The specification of 12V BMS in series or in parallel.

A: In series or in parallel is available but only individually4 BMS is limited in series but no limit in parallel

Q: About firmware program upgrade

A: Not allow to upgrade the Firmware program without permission,after sales service is not available if its cause any damage

Q: The temperature shows at-50°℃

A: NTC temperature sensor damaged or welding disengaged

Q: The conditions to use one key to power on/off

A: Master BMS can control slave one to power on or off when battery working in parallel.it could not be one key to power on off if master address is not dial the new version BMS can be dial automatically) and all BMS is not in standby model (because current of the battery will flow each other if there is not in standby mode when in parallel)

Q: ls it the BMS can change to another model to use by load the parameter

A: NO(such as 13S and 14S,15S and 16S can be changed by load the parameter but this will not recommended because it could be lead to malfunction)

Q: Running normal but there is bus bar over voltage warming

A: Please check if battery circuit connection is correct

Q: ls there any other way can know the status of BMS

A: 1.browse on PC software.2.check the message on LCD screen.3.check the status of LED in BMS as description of manual)

 